AIS embedded private keys enable practitioner impersonation
Products / packages CompuGroup Medical Infantia · CompuGroup Medical Profim · CompuGroup Medical Venere · 1 more
Published
Severity and exploitation
KEV coverage does not rule out exploitation.
Assessment vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:USeverity
high8.0CVSS measures technical severity, not the likelihood of an attack.
Known exploitation
Not listed in the checked CISA KEV catalog
Absence from CISA KEV does not rule out attacks.
Public exploit
Not established by this record
Missing evidence does not mean no public exploit exists.
Remediation
Fix status not established
No structured fix or guidance is available here. Check the latest publisher advisory.
What this means
CompuGroup Medical products (Infantia, Profim, Venere, Phronesis) versions 0 to 6.09.1 and 0 to 5.1.1 have embedded private keys that can be used to sign practitioner assertions, enabling unauthorized practitioner token requests. The weakness is due to the use of a shared password to protect the private keys. An attacker with access to the private keys can impersonate a practitioner.
Summarized by @cf/meta/llama-3.3-70b-instruct-fp8-fast. Verify details against the original sources.Attack conditions
No attack-condition excerpt has been identified here. Review the full source description and references for authentication, network access, and configuration requirements.
Review supporting sources →Affected versions
Check the exact model, release, and any platform requirements against your installation.
CompuGroup Medical · ENISA
Infantia
1 range
CompuGroup Medical · ENISA
Infantia
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 6.09.1
semver versions
Other versions: unknown
CompuGroup Medical · ENISA
Profim
1 range
CompuGroup Medical · ENISA
Profim
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 6.09.1
semver versions
Other versions: unknown
CompuGroup Medical · ENISA
Venere
1 range
CompuGroup Medical · ENISA
Venere
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 6.09.1
semver versions
Other versions: unknown
CompuGroup Medical · ENISA
Phronesis
1 range
CompuGroup Medical · ENISA
Phronesis
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 6.09.1
semver versions
Other versions: unknown
CompuGroup Medical · ENISA
Infantia
1 range
CompuGroup Medical · ENISA
Infantia
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 5.1.1
semver versions
Other versions: unknown
CompuGroup Medical · ENISA
Profim
1 range
CompuGroup Medical · ENISA
Profim
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 5.1.1
semver versions
Other versions: unknown
CompuGroup Medical · ENISA
Venere
1 range
CompuGroup Medical · ENISA
Venere
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 5.1.1
semver versions
Other versions: unknown
CompuGroup Medical · ENISA
Phronesis
1 range
CompuGroup Medical · ENISA
Phronesis
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 5.1.1
semver versions
Other versions: unknown
What to do
Compare your installed product and version with the affected versions above. A matching product name alone does not confirm exposure.
No structured fix or remediation guidance is available here. Check the full source description and vendor’s latest advisory for a patch or workaround; do not assume another version is safe.
cve.new guidance unless attributed to a publisher. This page does not inspect your installation.
Public exploit evidence
No public exploit reference is identified in the imported evidence. This is not a claim that no exploit exists.
Original source description
Read the full publisher description
Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests.
References
2 sourcesInside the record
Evidence available
Describes the evidence in this view, not whether the product is safe.
Original records
CVE-2026-118460View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.
cve.new JSON →Underlying weaknesses
The source’s classification of what caused the vulnerability.
Contributing organizations · 2
Assigning organization
Additional data publisher
Timeline
All times UTCAdvisory published
Publication date supplied by the source.
Source updated
Latest modification date supplied by the source.
Last imported by cve.new
Latest catalog import, not the date we first saw this advisory.
What changed
Follow changes- CVE · CVE-2026-118460
Observed 2026-11-12T23:58:17.231Z · upstream updated 2026-11-12T16:07:25.645Z
Prioritization updated
before
[]
after
[ { "source": "CISA-ADP", "type": "SSVC", "role": "CISA Coordinator", "timestamp": "2026-11-12T16:07:00.394183Z", "decisions": [ { "name": "Exploitation", "value": "none" }, { "name": "Automatable", "value": "yes" }, { "name": "Technical Impact", "value": "total" } ] } ]
Large field values are marked as truncated previews. Original source snapshots remain retained.
Showing up to 50 most recent observed changes.