{"id":"CVE-2026-118460","aliases":[],"cve":{"records":[{"id":"CVE-2026-118460","source":"ENISA","state":"PUBLISHED","reasons":[],"replacements":[],"disputed":false,"unsupportedWhenAssigned":false,"reserved":"2026-10-28T08:46:25.411Z","published":"2026-11-09T11:48:31.899Z","modified":"2026-11-12T16:07:25.645Z"}],"publishers":[{"name":"ENISA","role":"CNA","organizationId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","modified":"2026-11-09T11:48:31.899Z"},{"name":"CISA-ADP","role":"ADP","organizationId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","modified":"2026-11-12T16:07:25.645Z"}],"references":[{"url":"https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html","tags":[],"source":"ENISA"},{"url":"https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical","tags":[],"source":"ENISA"}],"weaknesses":[{"id":"CWE-321","description":"CWE-321","source":"ENISA"}],"applicability":[],"prioritization":[{"source":"CISA-ADP","type":"SSVC","role":"CISA Coordinator","timestamp":"2026-11-12T16:07:00.394183Z","decisions":[{"name":"Exploitation","value":"none"},{"name":"Automatable","value":"yes"},{"name":"Technical Impact","value":"total"}]}]},"title":"AIS embedded private keys enable practitioner impersonation","titleSource":"ENISA","descriptionSource":"ENISA","description":"Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests.","score":8,"severity":"high","published":"2026-11-09T11:48:31.899Z","modified":"2026-11-12T16:07:25.645Z","withdrawn":false,"knownExploited":false,"affected":[],"products":[{"vendor":"CompuGroup Medical","name":"Infantia","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"6.09.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"},{"vendor":"CompuGroup Medical","name":"Profim","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"6.09.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"},{"vendor":"CompuGroup Medical","name":"Venere","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"6.09.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"},{"vendor":"CompuGroup Medical","name":"Phronesis","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"6.09.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"},{"vendor":"CompuGroup Medical","name":"Infantia","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"},{"vendor":"CompuGroup Medical","name":"Profim","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"},{"vendor":"CompuGroup Medical","name":"Venere","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"},{"vendor":"CompuGroup Medical","name":"Phronesis","platforms":[],"versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.1","versionType":"semver"}],"defaultStatus":"unknown","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"}],"remediation":[],"references":["https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html","https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"],"sources":[{"name":"CVE","id":"CVE-2026-118460","modified":"2026-11-12T16:07:25.645Z","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"}],"assessments":[{"source":"ENISA","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U","score":8}],"sourceAffected":[],"observedAt":"2026-11-12T23:58:17.231Z","kev":{"status":"not-listed","checkedAt":"2026-11-14T22:00:33.590Z"},"coverage":[{"source":"NVD","status":"no-result","checkedAt":"2026-11-09T12:10:53.949Z","attemptedAt":"2026-11-09T12:10:53.949Z"},{"source":"GHSA","status":"no-result","checkedAt":"2026-11-09T12:10:35.438Z","attemptedAt":"2026-11-09T12:10:35.438Z"},{"source":"EUVD","status":"no-result","checkedAt":"2026-11-09T12:10:35.771Z","attemptedAt":"2026-11-09T12:10:35.771Z"},{"source":"EPSS","status":"no-result","checkedAt":"2026-11-09T12:10:35.503Z","attemptedAt":"2026-11-09T12:10:35.503Z"}],"evidence":[],"aiSummary":{"text":"CompuGroup Medical products (Infantia, Profim, Venere, Phronesis) versions 0 to 6.09.1 and 0 to 5.1.1 have embedded private keys that can be used to sign practitioner assertions, enabling unauthorized practitioner token requests. The weakness is due to the use of a shared password to protect the private keys. An attacker with access to the private keys can impersonate a practitioner.","model":"@cf/meta/llama-3.3-70b-instruct-fp8-fast","generatedAt":"2026-11-09T12:06:05.770Z","sources":[{"name":"CVE","url":"https://www.cve.org/CVERecord?id=CVE-2026-118460"}]}}