Investigate in your agent.

Turn this advisory into a focused investigation. Ask your agent to check your project’s versions, explain the evidence, and suggest a compatible fix.

Your agent needs remote MCP support and access to https://cve.new/mcp.

Read the setup guide

Skip to content
Check your stack
CVE-2024-49849

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions),…

Products / packages Siemens SIMATIC S7-PLCSIM V16 · Siemens SIMATIC S7-PLCSIM V17 · Siemens SIMATIC STEP 7 Safety V16 · 36 more

Published

Share

Severity and exploitation

Not in CISA KEV

KEV coverage does not rule out exploitation.

KEV checked 29/11/2026, 21:00:32 UTC
siemens · CVSS:3.1 · 7.8
Assessment vectorCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
siemens · CVSS:4.0 · 8.4
Assessment vectorCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
The headline uses the highest imported catalog score. Assessments can differ by source and CVSS version.

Severity

high8.4

CVSS measures technical severity, not the likelihood of an attack.

Known exploitation

Not listed in the checked CISA KEV catalog

Absence from CISA KEV does not rule out attacks.

Public exploit

Not established by this record

Missing evidence does not mean no public exploit exists.

Remediation

Fix status not established

No structured fix or guidance is available here. Check the latest publisher advisory.

What this means

A vulnerability has been identified in various Siemens products, including SIMATIC and SINAMICS, where affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion. Affected versions vary by product.

Summarized by @cf/meta/llama-3.3-70b-instruct-fp8-fast. Verify details against the original sources.

Attack conditions

No attack-condition excerpt has been identified here. Review the full source description and references for authentication, network access, and configuration requirements.

Review supporting sources →

Affected versions

Check the exact model, release, and any platform requirements against your installation.

Siemens · siemens

SIMATIC S7-PLCSIM V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-PLCSIM V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 Safety V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 Safety V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 Safety V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 Safety V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMOCODE ES V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMOCODE ES V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMOCODE ES V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMOCODE ES V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMOTION SCOUT TIA V5.4

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMOTION SCOUT TIA V5.5

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMOTION SCOUT TIA V5.6

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIRIUS Safety ES V17 (TIA Portal)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIRIUS Safety ES V18 (TIA Portal)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIRIUS Safety ES V19 (TIA Portal)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIRIUS Soft Starter ES V17 (TIA Portal)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIRIUS Soft Starter ES V18 (TIA Portal)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIRIUS Soft Starter ES V19 (TIA Portal)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Cloud V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Cloud V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V6.0.0.0

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Cloud V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V6.3.0.2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Cloud V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V5.2.1.1

custom versions

unaffected

unknown

Other versions: unknown

Automatic dependency matching is unavailable for this record. Use the product evidence and publisher’s instructions to check your installation.

What to do

Compare your installed product and version with the affected versions above. A matching product name alone does not confirm exposure.

No structured fix or remediation guidance is available here. Check the full source description and vendor’s latest advisory for a patch or workaround; do not assume another version is safe.

cve.new guidance unless attributed to a publisher. This page does not inspect your installation.

Public exploit evidence

No public exploit reference is identified in the imported evidence. This is not a claim that no exploit exists.

Original source description

Read the full publisher description

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions),…

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

References

1 sources

Inside the record

Evidence available

Package identity · not supplied
Version evidence
Remediation guidance · not supplied
Weakness classification
Additional publishers

Describes the evidence in this view, not whether the product is safe.

Original records

CVE-2024-49849

View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.

cve.new JSON →

Underlying weaknesses

The source’s classification of what caused the vulnerability.

CWE-502 ↗

CWE-502: Deserialization of Untrusted Data

siemens

Related →
Contributing organizations · 2
siemens

Assigning organization

2026-11-10
CISA-ADP

Additional data publisher

2024-12-11

Timeline

All times UTC
  1. Advisory published

    Publication date supplied by the source.

  2. Source updated

    Latest modification date supplied by the source.

  3. Last imported by cve.new

    Latest catalog import, not the date we first saw this advisory.

What changed

Follow changes
No substantive changes have been recorded here yet. History starts when cve.new observes a change after tracking is enabled; earlier edits are not reconstructed.

Large field values are marked as truncated previews. Original source snapshots remain retained.

Recent advisories affecting the same package or the same recorded vendor and product. These are separate vulnerabilities, not additional evidence for this advisory.

high8.5
CVE-2025-40759

A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17…

A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

No structured fix or guidance is available here. Check the latest publisher advisory.

Exploitation not established

Siemens · SIMATIC S7-PLCSIM V17 / Siemens · SIMATIC STEP 7 V17
high8.5
CVE-2025-30033

The affected setup component is vulnerable to DLL hijacking.

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

No structured fix or guidance is available here. Check the latest publisher advisory.

Exploitation not established

Siemens · Automation License Manager V6.0 / Siemens · Automation License Manager V6.2
high8.6
CVE-2024-54678

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions),…

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.

No structured fix or guidance is available here. Check the latest publisher advisory.

Exploitation not established

Siemens · SIMATIC PCS neo V4.1 / Siemens · SIMATIC PCS neo V5.0