Investigate in your agent.

Turn this advisory into a focused investigation. Ask your agent to check your project’s versions, explain the evidence, and suggest a compatible fix.

Your agent needs remote MCP support and access to https://cve.new/mcp.

Read the setup guide

Skip to content
Check your stack
CVE-2025-30033

The affected setup component is vulnerable to DLL hijacking.

Products / packages Siemens Automation License Manager V6.0 · Siemens Automation License Manager V6.2 · Siemens CEMAT V10.0 · 136 more

Published

Share

Severity and exploitation

Not in CISA KEV

KEV coverage does not rule out exploitation.

KEV checked 29/11/2026, 20:50:32 UTC
siemens · CVSS:3.1 · 7.8
Assessment vectorCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
siemens · CVSS:4.0 · 8.5
Assessment vectorCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
The headline uses the highest imported catalog score. Assessments can differ by source and CVSS version.

Severity

high8.5

CVSS measures technical severity, not the likelihood of an attack.

Known exploitation

Not listed in the checked CISA KEV catalog

Absence from CISA KEV does not rule out attacks.

Public exploit

Not established by this record

Missing evidence does not mean no public exploit exists.

Remediation

Fix status not established

No structured fix or guidance is available here. Check the latest publisher advisory.

What this means

The setup component in various Siemens products is vulnerable to DLL hijacking, which could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component. Affected products include SIMATIC and SINAMICS devices with versions less than the specified updates.

Summarized by @cf/meta/llama-3.3-70b-instruct-fp8-fast. Verify details against the original sources.

Attack conditions

No attack-condition excerpt has been identified here. Review the full source description and references for authentication, network access, and configuration requirements.

Review supporting sources →

Affected versions

Check the exact model, release, and any platform requirements against your installation.

Siemens · siemens

Automation License Manager V6.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Automation License Manager V6.2

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V6.2 Upd3

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

CEMAT V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

CP PtP Param configuring interface

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Create MyConfig (CMC)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V6.9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Energy Support Library (EnSL)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

FM Configuration Package

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Modular PID CTRL Tool

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

MultiFieldbus Configuration Tool (MFCT)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V1.5.5.0

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

OpenPCS 7 V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

OpenPCS 7 V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Siemens Network Planner (SINETPLAN)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V2.0 SP2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Automation Tool

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V5.0 SP4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Automation Tool SDK Windows

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V5.0 SP4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC BATCH V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC BATCH V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Control Function Library (CFL) V1.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Control Function Library (CFL) V2.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Control Function Library (CFL) V3.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V3.1.0.2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Control Function Library (CFL) V4.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V4.1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC D7-SYS

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V10.0 SP1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC eaSie Document Skills V26

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC eaSie PCS 7 Skill Package V26 (6DL5424-0BX00-0AV8)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC eaSie Workflow Skills V26

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Energy Suite V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Energy Suite V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Energy Suite V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Logon V1.6

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Logon V2.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V2.0 Upd3

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Management Agent

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 SP1 Upd8

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Management Console

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 SP1 Upd8

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC MTP CREATOR V2.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V2.1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC MTP CREATOR V3.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC MTP CREATOR V4.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V4.1.0.1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC MTP CREATOR V5.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V5.0.0.1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC MTP Integrator V1.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC MTP Integrator V2.x

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC NET PC Software V16

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC NET PC Software V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC NET PC Software V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC NET PC Software V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC NET PC Software V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V20.0 Update 1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC ODK 1500S

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Advanced Process Faceplates V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 SP2 Upd4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Advanced Process Functions V2.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Advanced Process Functions V2.2

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Advanced Process Graphics V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Advanced Process Graphics V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Advanced Process Library V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 SP2 Upd6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Basis Faceplates V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 SP2 Upd2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Basis Library V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V10.0 SP1 Upd2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Basis Library V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 SP2 Upd8

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Industry Library V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Industry Library V9.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Industry Library V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Logic Matrix V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Logic Matrix V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 Upd8

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 MPC Configurator

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 PowerControl V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Standard Chemical Library V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 Standard Chemical Library V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 TeleControl V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V10.0 SP1 UC01

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7 V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.1 SP1 UC08

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS 7/OPEN OS V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS neo V5.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PCS neo V6.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V6.0 SP1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PDM Maintenance Station V5.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PDM V9.2

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC PDM V9.3

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V9.3 SP1 Upd2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Process Function Library (PFL) V4.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Process Historian 2020

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Process Historian 2022

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Process Historian 2024

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V2024 SP1 Upd2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC ProSave V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC ProSave V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC ProSave V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC ProSave V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Route Control V10.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Route Control V9.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7 F Systems V6.3

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7 F Systems V6.4

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-1500 Software Controller V2

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-1500 Software Controller V3

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V31.1.5

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V4.0.1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-PCT

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V3.5 SP4 Update 1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-PLCSIM Advanced

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V7.0 Update 1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-PLCSIM V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-PLCSIM V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-PLCSIM V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC S7-PLCSIM V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V20 Update 1

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Safety Matrix V6.3

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 CFC V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 CFC V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC STEP 7 V5.7

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC Target

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V6.0 SP3

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC flexible ES

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Runtime Advanced

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Runtime Professional

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V21

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Runtime Professional V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC TeleControl

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified Line Coordination

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V20

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified PC Runtime V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified PC Runtime V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified PC Runtime V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Unified Sequence

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V20

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC V7.5

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V7.5 SP2 Update 20

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC V8.0

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V8.0 Update 8

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC V8.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V8.1 Update 3

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Visualization Architect (SiVArc) V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Visualization Architect (SiVArc) V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Visualization Architect (SiVArc) V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMATIC WinCC Visualization Architect (SiVArc) V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V20 Update 3

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMIT Rapid Tester

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SIMIT Simulation Platform

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINAMICS Startdrive V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINEC NMS

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V4.0

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SINEMA Remote Connect Client

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

SITRANS

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Standard PID CTRL Tool

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TeleControl Server Basic V3.1

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V3.1.2.2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Administrator

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V3.0.6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Cloud Connector

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V2.3

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Test Suite V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Test Suite V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Test Suite V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Portal Test Suite V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V20 Update 3

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Project-Server

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V2.2

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

TIA Project-Server V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before *

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Totally Integrated Automation Portal (TIA Portal) V17

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Totally Integrated Automation Portal (TIA Portal) V18

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V18 Update 6

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Totally Integrated Automation Portal (TIA Portal) V19

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V19 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

Totally Integrated Automation Portal (TIA Portal) V20

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V20 Update 4

custom versions

unaffected

unknown

Other versions: unknown

Siemens · siemens

WinCC Panel Image Setup

1 range

Compare with this publisher’s ranges. This does not inspect your installation.

affected

0 → before V17 Update 9

custom versions

unaffected

unknown

Other versions: unknown

Automatic dependency matching is unavailable for this record. Use the product evidence and publisher’s instructions to check your installation.

What to do

Compare your installed product and version with the affected versions above. A matching product name alone does not confirm exposure.

No structured fix or remediation guidance is available here. Check the full source description and vendor’s latest advisory for a patch or workaround; do not assume another version is safe.

cve.new guidance unless attributed to a publisher. This page does not inspect your installation.

Public exploit evidence

No public exploit reference is identified in the imported evidence. This is not a claim that no exploit exists.

Original source description

Read the full publisher description

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

References

1 sources

Inside the record

Evidence available

Package identity · not supplied
Version evidence
Remediation guidance · not supplied
Weakness classification
Additional publishers

Describes the evidence in this view, not whether the product is safe.

Original records

CVE-2025-30033

View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.

cve.new JSON →

Underlying weaknesses

The source’s classification of what caused the vulnerability.

CWE-427 ↗

CWE-427: Uncontrolled Search Path Element

siemens

Related →
Contributing organizations · 2
siemens

Assigning organization

2026-11-10
CISA-ADP

Additional data publisher

2025-08-12

Timeline

All times UTC
  1. Advisory published

    Publication date supplied by the source.

  2. Source updated

    Latest modification date supplied by the source.

  3. Last imported by cve.new

    Latest catalog import, not the date we first saw this advisory.

What changed

Follow changes
No substantive changes have been recorded here yet. History starts when cve.new observes a change after tracking is enabled; earlier edits are not reconstructed.

Large field values are marked as truncated previews. Original source snapshots remain retained.

Recent advisories affecting the same package or the same recorded vendor and product. These are separate vulnerabilities, not additional evidence for this advisory.

high8.5
CVE-2026-59082

A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC…

A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device.

No structured fix or guidance is available here. Check the latest publisher advisory.

Exploitation not established

Siemens · SIMATIC WinCC V7.5 / Siemens · SIMATIC WinCC V8.0
high7.7
CVE-2026-58114

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All…

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.

No structured fix or guidance is available here. Check the latest publisher advisory.

Exploitation not established

Siemens · SIMATIC BATCH V9.1 / Siemens · SIMATIC Information Server 2020
critical9.8
CVE-2026-111497 Known exploitedPackage fixes recorded

Brotli: Out-of-bounds write in the Brotli decoder ("Node2Shell") also affects the PyPI Brotli package

In github.com/andybalholm/brotli before v1.2.7, the decompressor allocates memory for Huffman tables and block-type trees on every meta-block header without bounding the cumulative allocations relative to the input size. A small crafted brotli stream containing many empty meta-blocks with new Huffman trees can trigger hundreds of megabytes of allocations per kilobyte of input, leading to denial of service.

Recorded fixes — brotli: 1.2.1; brotlicffi: 1.2.1.0; 1 more packages. Check your release branch.

critical9.8
CVE-2025-15467

Stack buffer overflow in CMS (Auth)EnvelopedData parsing

Issue summary: Parsing CMS AuthEnvelopedData or EnvelopedData message with maliciously crafted AEAD parameters can trigger a stack buffer overflow.

Review the recorded instructions. Guidance may be a workaround rather than a fixed version.

Public exploit reference

OpenSSL · OpenSSL / Siemens · AI Lightweight Inference Server
high8.5
CVE-2025-40759

A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17…

A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

No structured fix or guidance is available here. Check the latest publisher advisory.

Exploitation not established

Siemens · SIMATIC S7-PLCSIM V17 / Siemens · SIMATIC STEP 7 V17
high8.6
CVE-2024-54678

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions),…

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.

No structured fix or guidance is available here. Check the latest publisher advisory.

Exploitation not established

Siemens · SIMATIC PCS neo V4.1 / Siemens · SIMATIC PCS neo V5.0