{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-82948","assignerOrgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","state":"PUBLISHED","assignerShortName":"ENISA","dateReserved":"2026-08-31T12:26:22.054Z","datePublished":"2026-11-19T10:30:43.109Z","dateUpdated":"2026-11-19T15:10:24.881Z"},"containers":{"cna":{"providerMetadata":{"orgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","shortName":"ENISA","dateUpdated":"2026-11-19T10:30:43.109Z"},"title":"RF Replay of control commands","problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-294","description":"CWE-294: Authentication Bypass by Capture-replay","type":"CWE"}]}],"affected":[{"vendor":"Onyx Cookware ApS","product":"Nexsmart Guardian 2 (Alarm system)","versions":[{"status":"affected","version":"0","versionType":"semver"}],"defaultStatus":"affected"}],"descriptions":[{"lang":"en","value":"The Guardian 2 alarm unit lacks a mechanism to\nauthenticate control commands sent over 433.92 MHz, which allows an attacker to\nreplay the static commands to impersonate activity.  The attacker can also disarm or arm the\nsystem at will if a Nexsmart keypad (product link) is in use, thus compromising\nthe functionality of the alarm system completely.","supportingMedia":[{"type":"text/html","base64":false,"value":"<p>The Guardian 2 alarm unit lacks a mechanism to\nauthenticate control commands sent over 433.92 MHz, which allows an attacker to\nreplay the static commands to impersonate activity.<span>&nbsp; </span>The attacker can also disarm or arm the\nsystem at will if a Nexsmart keypad (product link) is in use, thus compromising\nthe functionality of the alarm system completely.</p>"}]}],"references":[{"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"HIGH","baseScore":7.1,"vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N"}}],"solutions":[{"lang":"en","value":"Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.","supportingMedia":[{"type":"text/html","base64":false,"value":"<i><span>Nexsmart reported suspending sales and described a phase-out of the current Guardian models.&nbsp;</span><span>If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance.</span></i>"}]}],"credits":[{"lang":"en","value":"Elias Lindström","type":"finder"},{"lang":"en","value":"CERT-SE","type":"coordinator"}],"x_generator":{"engine":"Vulnogram 1.0.5"},"source":{"discovery":"UNKNOWN"},"datePublic":"2026-11-19T09:00:00.000Z"},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-11-19T15:10:15.653657Z","id":"CVE-2026-82948","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-11-19T15:10:24.881Z"}}]}}