{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-47711","assignerOrgId":"a0819718-46f1-4df5-94e2-005712e83aaa","state":"PUBLISHED","assignerShortName":"GitHub_M","dateReserved":"2026-05-19T21:29:25.481Z","datePublished":"2026-11-12T20:05:20.110Z","dateUpdated":"2026-11-13T00:31:30.671Z"},"containers":{"cna":{"title":"BACnet Stack: Stack buffer overflow in Loop internal ReadProperty path via Life_Safety_Zone.accepted-modes on the default BACnet/IP server","problemTypes":[{"descriptions":[{"cweId":"CWE-121","lang":"en","description":"CWE-121: Stack-based Buffer Overflow","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-131","lang":"en","description":"CWE-131: Incorrect Calculation of Buffer Size","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-787","lang":"en","description":"CWE-787: Out-of-bounds Write","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-805","lang":"en","description":"CWE-805: Buffer Access with Incorrect Length Value","type":"CWE"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.6,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","version":"3.1"}}],"references":[{"name":"https://github.com/bacnet-stack/bacnet-stack/security/advisories/GHSA-vrpm-9gm2-x552","tags":["x_refsource_CONFIRM"],"url":"https://github.com/bacnet-stack/bacnet-stack/security/advisories/GHSA-vrpm-9gm2-x552"}],"affected":[{"vendor":"bacnet-stack","product":"bacnet-stack","versions":[{"version":"< 1.4.4","status":"affected"},{"version":"< 1.5.1","status":"affected"},{"version":"< 1.6.0","status":"affected"}]}],"providerMetadata":{"orgId":"a0819718-46f1-4df5-94e2-005712e83aaa","shortName":"GitHub_M","dateUpdated":"2026-11-12T20:05:20.110Z"},"descriptions":[{"lang":"en","value":"BACnet Stack is a BACnet open source protocol stack C library for embedded systems. Prior to versions 1.4.4, 1.5.1, and 1.6.0, the current master demo server can be crashed remotely over BACnet/IP by sending a valid Confirmed WriteProperty request that updates loop-1's controlled-variable-reference to point to life-safety-zone-1 / accepted-modes. This issue has been patched in versions 1.4.4, 1.5.1, and 1.6.0."}],"source":{"advisory":"GHSA-vrpm-9gm2-x552","discovery":"UNKNOWN"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-11-13T00:31:09.971913Z","id":"CVE-2026-47711","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-11-13T00:31:30.671Z"}}]}}