{"id":"CVE-2026-118792","aliases":[],"cve":{"records":[{"id":"CVE-2026-118792","source":"ENISA","state":"PUBLISHED","reasons":[],"replacements":[],"disputed":false,"unsupportedWhenAssigned":false,"reserved":"2026-10-28T19:53:57.995Z","published":"2026-11-09T12:04:16.675Z","modified":"2026-11-12T16:04:57.172Z"}],"publishers":[{"name":"ENISA","role":"CNA","organizationId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","modified":"2026-11-09T12:04:16.675Z"},{"name":"CISA-ADP","role":"ADP","organizationId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","modified":"2026-11-12T16:04:57.172Z"}],"references":[{"url":"https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical","tags":[],"source":"ENISA"},{"url":"https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html","tags":[],"source":"ENISA"}],"weaknesses":[{"id":"CWE-1392","description":"CWE-1392","source":"ENISA"}],"applicability":[],"prioritization":[{"source":"CISA-ADP","type":"SSVC","role":"CISA Coordinator","timestamp":"2026-11-12T16:04:44.361327Z","decisions":[{"name":"Exploitation","value":"none"},{"name":"Automatable","value":"no"},{"name":"Technical Impact","value":"total"}]}]},"title":"Default ODBC credentials","titleSource":"ENISA","descriptionSource":"ENISA","description":"Default credentials permit access through AcuXDBC.","score":6.1,"severity":"medium","published":"2026-11-09T12:04:16.675Z","modified":"2026-11-12T16:04:57.172Z","withdrawn":false,"knownExploited":false,"affected":[],"products":[{"vendor":"CompuGroup Medical","name":"Wingesfar","platforms":[],"versions":[{"version":"0","status":"affected","lessThan":"2026.07a","versionType":"custom"}],"defaultStatus":"unaffected","cpes":[],"source":"ENISA","url":"https://www.cve.org/CVERecord?id=CVE-2026-118792"}],"remediation":[],"references":["https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical","https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"],"sources":[{"name":"CVE","id":"CVE-2026-118792","modified":"2026-11-12T16:04:57.172Z","url":"https://www.cve.org/CVERecord?id=CVE-2026-118792"}],"assessments":[{"source":"ENISA","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U","score":6.1}],"sourceAffected":[],"observedAt":"2026-11-12T23:58:22.031Z","kev":{"status":"not-listed","checkedAt":"2026-11-15T00:40:33.739Z"},"coverage":[{"source":"NVD","status":"no-result","checkedAt":"2026-11-09T12:30:36.806Z","attemptedAt":"2026-11-09T12:30:36.806Z"},{"source":"GHSA","status":"no-result","checkedAt":"2026-11-09T12:30:36.803Z","attemptedAt":"2026-11-09T12:30:36.803Z"},{"source":"EUVD","status":"no-result","checkedAt":"2026-11-09T12:30:37.464Z","attemptedAt":"2026-11-09T12:30:37.464Z"},{"source":"EPSS","status":"no-result","checkedAt":"2026-11-09T12:30:36.575Z","attemptedAt":"2026-11-09T12:30:36.575Z"}],"evidence":[],"aiSummary":{"text":"CompuGroup Medical's Wingesfar version 0, before 2026.07a, has default ODBC credentials, allowing access through AcuXDBC. The impact is unclear. Local access may be required.","model":"@cf/meta/llama-3.3-70b-instruct-fp8-fast","generatedAt":"2026-11-09T12:21:08.898Z","sources":[{"name":"CVE","url":"https://www.cve.org/CVERecord?id=CVE-2026-118792"}]}}