{"id":"CVE-2026-118608","aliases":[],"cve":{"records":[{"id":"CVE-2026-118608","source":"zdi","state":"PUBLISHED","reasons":[],"replacements":[],"disputed":false,"unsupportedWhenAssigned":false,"reserved":"2026-10-28T16:49:08.374Z","published":"2026-10-28T16:50:34.964Z","modified":"2026-10-28T16:50:34.964Z"}],"publishers":[{"name":"zdi","role":"CNA","organizationId":"99f1926a-a320-47d8-bbb5-42feb611262e","modified":"2026-10-28T16:50:34.964Z"}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-826/","tags":["x_research-advisory"],"source":"zdi"}],"weaknesses":[{"id":"CWE-125","description":"CWE-125: Out-of-bounds Read","source":"zdi"}],"applicability":[],"prioritization":[]},"title":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability","titleSource":"zdi","descriptionSource":"zdi","description":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Alpine iLX-F511 devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the prh_rfcomm_cc_process_test function. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-29018.","score":3.5,"severity":"low","published":"2026-10-28T16:50:34.964Z","modified":"2026-10-28T16:50:34.964Z","withdrawn":false,"knownExploited":false,"affected":[],"products":[{"vendor":"Alpine","name":"iLX-F511","platforms":[],"versions":[{"version":"7.0.000","status":"affected"}],"defaultStatus":"unknown","cpes":[],"source":"zdi","url":"https://www.cve.org/CVERecord?id=CVE-2026-118608"}],"remediation":[],"references":["https://www.zerodayinitiative.com/advisories/ZDI-26-826/"],"sources":[{"name":"CVE","id":"CVE-2026-118608","modified":"2026-10-28T16:50:34.964Z","url":"https://www.cve.org/CVERecord?id=CVE-2026-118608"}],"assessments":[{"source":"zdi","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","score":3.5}],"sourceAffected":[],"observedAt":"2026-10-29T14:37:28.632Z","kev":{"status":"not-listed","checkedAt":"2026-10-31T11:10:32.450Z"},"coverage":[{"source":"NVD","status":"not-checked"},{"source":"GHSA","status":"not-checked"},{"source":"EUVD","status":"not-checked"},{"source":"EPSS","status":"not-checked"}],"evidence":[],"aiSummary":{"text":"Alpine iLX-F511 version 7.0.000 has an out-of-bounds read vulnerability in libanwbtstack.so, allowing network-adjacent attackers to disclose sensitive information after pairing a malicious Bluetooth device. The issue is due to lack of proper validation of user-supplied data. An attacker must first obtain the ability to pair with the target system.","model":"@cf/meta/llama-3.3-70b-instruct-fp8-fast","generatedAt":"2026-10-30T09:26:33.064Z","sources":[{"name":"CVE","url":"https://www.cve.org/CVERecord?id=CVE-2026-118608"}]}}