{"id":"CVE-2026-118604","aliases":[],"cve":{"records":[{"id":"CVE-2026-118604","source":"zdi","state":"PUBLISHED","reasons":[],"replacements":[],"disputed":false,"unsupportedWhenAssigned":false,"reserved":"2026-10-28T16:48:50.618Z","published":"2026-10-28T16:50:11.011Z","modified":"2026-10-28T16:50:11.011Z"}],"publishers":[{"name":"zdi","role":"CNA","organizationId":"99f1926a-a320-47d8-bbb5-42feb611262e","modified":"2026-10-28T16:50:11.011Z"}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-822/","tags":["x_research-advisory"],"source":"zdi"}],"weaknesses":[{"id":"CWE-121","description":"CWE-121: Stack-based Buffer Overflow","source":"zdi"}],"applicability":[],"prioritization":[]},"title":"Alpine iLX-F511 Framework Service Stack-based Buffer Overflow Remote Code Execution Vulnerability","titleSource":"zdi","descriptionSource":"zdi","description":"Alpine iLX-F511 Framework Service Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Alpine iLX-F511 devices. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the framework service. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-29007.","score":6.8,"severity":"medium","published":"2026-10-28T16:50:11.011Z","modified":"2026-10-28T16:50:11.011Z","withdrawn":false,"knownExploited":false,"affected":[],"products":[{"vendor":"Alpine","name":"iLX-F511","platforms":[],"versions":[{"version":"7.0.000","status":"affected"}],"defaultStatus":"unknown","cpes":[],"source":"zdi","url":"https://www.cve.org/CVERecord?id=CVE-2026-118604"}],"remediation":[],"references":["https://www.zerodayinitiative.com/advisories/ZDI-26-822/"],"sources":[{"name":"CVE","id":"CVE-2026-118604","modified":"2026-10-28T16:50:11.011Z","url":"https://www.cve.org/CVERecord?id=CVE-2026-118604"}],"assessments":[{"source":"zdi","vector":"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","score":6.8}],"sourceAffected":[],"observedAt":"2026-10-29T14:37:28.632Z","kev":{"status":"not-listed","checkedAt":"2026-10-31T11:50:31.946Z"},"coverage":[{"source":"NVD","status":"not-checked"},{"source":"GHSA","status":"not-checked"},{"source":"EUVD","status":"not-checked"},{"source":"EPSS","status":"not-checked"}],"evidence":[],"aiSummary":{"text":"Alpine iLX-F511 devices with Framework Service version 7.0.000 have a stack-based buffer overflow weakness, allowing physically present attackers to execute arbitrary code without authentication. The issue is due to improper validation of user-supplied data. Attackers can leverage this to execute code as root.","model":"@cf/meta/llama-3.3-70b-instruct-fp8-fast","generatedAt":"2026-10-30T09:26:22.981Z","sources":[{"name":"CVE","url":"https://www.cve.org/CVERecord?id=CVE-2026-118604"}]}}