{"id":"CVE-2026-113362","aliases":[],"cve":{"records":[{"id":"CVE-2026-113362","source":"NEC","state":"PUBLISHED","reasons":[],"replacements":[],"disputed":false,"unsupportedWhenAssigned":false,"reserved":"2026-10-20T01:52:24.557Z","published":"2026-11-09T04:10:22.553Z","modified":"2026-11-10T14:10:50.204Z"}],"publishers":[{"name":"NEC","role":"CNA","organizationId":"f2760a35-e0d8-4637-ac4c-cc1a2de3e282","modified":"2026-11-09T04:10:22.553Z"},{"name":"CISA-ADP","role":"ADP","organizationId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","modified":"2026-11-10T14:10:50.204Z"}],"references":[{"url":"https://jpn.nec.com/security-info/secinfo/nv26-006_en.html","tags":[],"source":"NEC"}],"weaknesses":[{"id":"CWE-276","description":"CWE-276 Incorrect default permissions in the Prob","source":"NEC"}],"applicability":[],"prioritization":[{"source":"CISA-ADP","type":"SSVC","role":"CISA Coordinator","timestamp":"2026-11-10T14:10:38.797559Z","decisions":[{"name":"Exploitation","value":"none"},{"name":"Automatable","value":"no"},{"name":"Technical Impact","value":"total"}]}]},"title":"Improper Access Control in the program installation folder in NEC Corporation WebSAM Winshare Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver…","titleSource":"NEC","descriptionSource":"NEC","description":"Improper Access Control in the program installation folder in NEC Corporation WebSAM Winshare Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver 7.7.0 through 7.7.1 on Windows allows a locally authenticated low-privileged attacker to execute arbitrary code with SYSTEM privileges via a crafted DLL file that is loaded by a SYSTEM-level process.","score":8.5,"severity":"high","published":"2026-11-09T04:10:22.553Z","modified":"2026-11-10T14:10:50.204Z","withdrawn":false,"knownExploited":false,"affected":[],"products":[{"vendor":"NEC Corporation","name":"WebSAM WinShare","platforms":[],"versions":[{"version":"Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver 7.7.0 through 7.7.1","status":"affected"}],"defaultStatus":"unaffected","cpes":[],"source":"NEC","url":"https://www.cve.org/CVERecord?id=CVE-2026-113362"}],"remediation":[],"references":["https://jpn.nec.com/security-info/secinfo/nv26-006_en.html"],"sources":[{"name":"CVE","id":"CVE-2026-113362","modified":"2026-11-10T14:10:50.204Z","url":"https://www.cve.org/CVERecord?id=CVE-2026-113362"}],"assessments":[{"source":"NEC","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","score":8.5}],"sourceAffected":[],"observedAt":"2026-11-10T14:22:24.869Z","kev":{"status":"not-listed","checkedAt":"2026-11-16T00:10:31.802Z"},"coverage":[{"source":"NVD","status":"available","checkedAt":"2026-11-09T04:20:31.896Z","attemptedAt":"2026-11-09T04:20:31.896Z"},{"source":"GHSA","status":"no-result","checkedAt":"2026-11-09T04:20:32.708Z","attemptedAt":"2026-11-09T04:20:32.708Z"},{"source":"EUVD","status":"no-result","checkedAt":"2026-11-09T04:20:31.461Z","attemptedAt":"2026-11-09T04:20:31.461Z"},{"source":"EPSS","status":"no-result","checkedAt":"2026-11-09T04:20:32.708Z","attemptedAt":"2026-11-09T04:20:32.708Z"}],"evidence":[{"source":"NVD","id":"CVE-2026-113362","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-113362","modified":"2026-11-09T04:17:06.133","score":8.5,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","checkedAt":"2026-11-09T04:20:31.896Z"}],"aiSummary":{"text":"NEC WebSAM Winshare versions 7.5.0 and earlier (excluding 7.3.3), 7.6.0, and 7.7.0 through 7.7.1 have improper access control, allowing a locally authenticated attacker to execute arbitrary code with SYSTEM privileges. The attacker must have low-privileged access. The impact is code execution with elevated privileges.","model":"@cf/meta/llama-3.3-70b-instruct-fp8-fast","generatedAt":"2026-11-09T04:16:06.525Z","sources":[{"name":"CVE","url":"https://www.cve.org/CVERecord?id=CVE-2026-113362"}]}}