Use of default password based on serial number
Severity and exploitation
KEV coverage does not rule out exploitation.
Assessment vector
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:NSeverity
high8.7CVSS measures technical severity, not the likelihood of an attack.
Known exploitation
Not listed in the checked CISA KEV catalog
Absence from CISA KEV does not rule out attacks.
Public exploit
Not established by this record
Missing evidence does not mean no public exploit exists.
Remediation
Source guidance available
Review the recorded instructions. Guidance may be a workaround rather than a fixed version.
What this means
Delta UFC500 charging stations with versions less than 2.4.18 and 4.4.1 use default passwords based on the device serial number, allowing an unauthenticated attacker with adjacent network access to reconstruct the password and access sensitive settings. The weakness is due to the use of default credentials. An attacker can log in to read and change settings.
Summarized by @cf/meta/llama-3.3-70b-instruct-fp8-fast. Verify details against the original sources.Attack conditions
No attack-condition excerpt has been identified here. Review the full source description and references for authentication, network access, and configuration requirements.
Review supporting sources →Affected versions
Check the exact model, release, and any platform requirements against your installation.
Delta Electronics · DIVD
Delta UFC500
2 ranges
Delta Electronics · DIVD
Delta UFC500
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → before 2.4.18
semver versions
unaffected
2.4.18
Other versions: unknown
Delta Electronics · DIVD
Delta UFC500
1 range
Delta Electronics · DIVD
Delta UFC500
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → before 4.4.1
semver versions
Other versions: unaffected
What to do
Compare your installed product and version with the affected versions above. A matching product name alone does not confirm exposure.
Set a non-default password for the Service account.
Set a non-default password for the Service account.
cve.new guidance unless attributed to a publisher. This page does not inspect your installation.
Public exploit evidence
No public exploit reference is identified in the imported evidence. This is not a claim that no exploit exists.
Original source description
Read the full publisher description
Delta UFC500 charging stations derive the default credentials of the Service account from character positions of the device serial number. An unauthenticated attacker with adjacent network access can reconstruct the resulting password, or exhaust the keyspace, and log in to read and change sensitive settings such as the OCPP backend.
References
2 sourcesInside the record
Evidence available
Describes the evidence in this view, not whether the product is safe.
Original records
CVE-2026-22105View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.
cve.new JSON →Contributing organizations · 2
Assigning organization
Additional data publisher
Timeline
All times UTCAdvisory published
Publication date supplied by the source.
Source updated
Latest modification date supplied by the source.
Last imported by cve.new
Latest catalog import, not the date we first saw this advisory.
What changed
Follow changes- CVE · CVE-2026-22105
Observed 2026-10-30T17:32:23.801Z · upstream updated 2026-10-30T16:35:01.858Z
Prioritization updated
before
[]
after
[ { "source": "CISA-ADP", "type": "SSVC", "role": "CISA Coordinator", "timestamp": "2026-10-30T16:34:48.538711Z", "decisions": [ { "name": "Exploitation", "value": "none" }, { "name": "Automatable", "value": "no" }, { "name": "Technical Impact", "value": "total" } ] } ]
Large field values are marked as truncated previews. Original source snapshots remain retained.
Showing up to 50 most recent observed changes.