A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 = V11.12.6 < V11.12.7).
Severity and exploitation
KEV coverage does not rule out exploitation.
Assessment vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HAssessment vector
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NSeverity
critical9.2CVSS measures technical severity, not the likelihood of an attack.
Known exploitation
Not listed in the checked CISA KEV catalog
Absence from CISA KEV does not rule out attacks.
Public exploit
Not established by this record
Missing evidence does not mean no public exploit exists.
Remediation
Fix status not established
No structured fix or guidance is available here. Check the latest publisher advisory.
What this means
Mendix Studio Pro 11 versions 11.15.0 to 11.16.0 and 11.12.6 to 11.12.7 have a vulnerability where the MCP Server's HTTP listener is not restricted to the loopback interface. An attacker with network access may interact with the MCP Server remotely.
Summarized by @cf/meta/llama-3.3-70b-instruct-fp8-fast. Verify details against the original sources.Attack conditions
No attack-condition excerpt has been identified here. Review the full source description and references for authentication, network access, and configuration requirements.
Review supporting sources →Affected versions
Check the exact model, release, and any platform requirements against your installation.
Siemens · siemens
Mendix Studio Pro 11
1 range
Siemens · siemens
Mendix Studio Pro 11
Compare with this publisher’s ranges. This does not inspect your installation.
affected
V11.15.0 → before V11.16.0
custom versions
Other versions: unknown
Siemens · siemens
Mendix Studio Pro 11.12
1 range
Siemens · siemens
Mendix Studio Pro 11.12
Compare with this publisher’s ranges. This does not inspect your installation.
affected
V11.12.6 → before V11.12.7
custom versions
Other versions: unknown
What to do
Compare your installed product and version with the affected versions above. A matching product name alone does not confirm exposure.
No structured fix or remediation guidance is available here. Check the full source description and vendor’s latest advisory for a patch or workaround; do not assume another version is safe.
cve.new guidance unless attributed to a publisher. This page does not inspect your installation.
Public exploit evidence
No public exploit reference is identified in the imported evidence. This is not a claim that no exploit exists.
Original source description
Read the full publisher description
A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.
References
1 sourcesInside the record
Evidence available
Describes the evidence in this view, not whether the product is safe.
Original records
CVE-2026-112136View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.
cve.new JSON →Contributing organizations · 2
Assigning organization
Additional data publisher
Timeline
All times UTCAdvisory published
Publication date supplied by the source.
Source updated
Latest modification date supplied by the source.
Last imported by cve.new
Latest catalog import, not the date we first saw this advisory.
What changed
Follow changes- CVE · CVE-2026-112136
Observed 2026-11-10T16:36:47.139Z · upstream updated 2026-11-10T16:34:11.685Z
Prioritization updated
before
[]
after
[ { "source": "CISA-ADP", "type": "SSVC", "role": "CISA Coordinator", "timestamp": "2026-11-10T16:34:00.788095Z", "decisions": [ { "name": "Exploitation", "value": "none" }, { "name": "Automatable", "value": "no" }, { "name": "Technical Impact", "value": "total" } ] } ]
Large field values are marked as truncated previews. Original source snapshots remain retained.
Showing up to 50 most recent observed changes.