Infinite loop when reading PDPortDataCheck record of subslot 0
Impact
P-Net before 1.0.3 enters an infinite loop when handling a read request for the PDPortDataCheck record with subslot 0, causing a denial of service. A remote unauthenticated attacker can exploit this. The loop never completes, stopping the device from responding.
Summarized by @cf/meta/llama-3.3-70b-instruct-fp8-fast. Verify details against the original sources.What to do
Upgrade to P-Net 1.0.3 or later.
Affected packages
Affected products
Vendor version evidence. Product records are separate from automatic dependency matching.
RT-Labs · rt-labs
P-Net
1 range
RT-Labs · rt-labs
P-Net
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → before 1.0.3
semver versions
Other versions: unaffected
Original source description
P-Net before 1.0.3 enters an infinite loop when handling a read request for the PDPortDataCheck record with subslot 0 (whole module). The loop over the ports never advanced to the next port, so the request never completes and the device stops responding. A remote unauthenticated attacker can use this to cause a denial of service.
Inside the record
Evidence available
Describes the evidence in this view, not whether the product is safe.
Original records
CVE-2026-111731View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.
cve.new JSON →Underlying weaknesses
The source’s classification of what caused the vulnerability.
Contributing organizations · 1
Assigning organization
What changed
Follow changesLarge field values are marked as truncated previews. Original source snapshots remain retained.