Investigate in your agent.

Turn this advisory into a focused investigation. Ask your agent to check your project’s versions, explain the evidence, and suggest a compatible fix.

Your agent needs remote MCP support and access to https://cve.new/mcp.

Read the setup guide

Skip to content
Check your stack
CVE-2026-111594

InterSystems Corporation InterSystems IRIS for Health Cleartext Transmission of Sensitive Information

Products / packages InterSystems IRIS for Health

Published

Share

Severity and exploitation

Not in CISA KEV

KEV coverage does not rule out exploitation.

KEV checked 05/11/2026, 13:55:32 UTC
icscert · CVSS:3.1 · 8.1
Assessment vectorCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
icscert · CVSS:4.0 · 9.2
Assessment vectorCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
The headline uses the highest imported catalog score. Assessments can differ by source and CVSS version.

Severity

critical9.2

CVSS measures technical severity, not the likelihood of an attack.

Known exploitation

Not listed in the checked CISA KEV catalog

Absence from CISA KEV does not rule out attacks.

Public exploit

Not established by this record

Missing evidence does not mean no public exploit exists.

Remediation

Source guidance available

Review the recorded instructions. Guidance may be a workaround rather than a fixed version.

What this means

InterSystems IRIS for Health versions 2025.3.0.226, 2026.1.0.235, and 2026.2.0.221 have TLS/SSL encryption turned off by default, which may allow an attacker to view transmitted data. An attacker with access to the transmission path may use the data to log into the device. The weakness is related to cleartext transmission of sensitive information.

Summarized by @cf/meta/llama-3.3-70b-instruct-fp8-fast. Verify details against the original sources.

Attack conditions

No attack-condition excerpt has been identified here. Review the full source description and references for authentication, network access, and configuration requirements.

Review supporting sources →

Affected versions

Check the exact model, release, and any platform requirements against your installation.

InterSystems · icscert

IRIS for Health

3 ranges

Compare with this publisher’s ranges. This does not inspect your installation.

affected

2026.2.0.221

2026.1.0.235

2025.3.0.226

unaffected

unknown

Other versions: unaffected

Automatic dependency matching is unavailable for this record. Use the product evidence and publisher’s instructions to check your installation.

What to do

Compare your installed product and version with the affected versions above. A matching product name alone does not confirm exposure.

InterSystems recommends users configure IRIS superserver to require SSL/TLS: https://docs.intersystems.com/irislatest/csp/docbook/DocBook.UI.Page.cls?KEY=ROARS_gsecuring_checklist Note that there are three settings: "Disabled", which means that client communications do not use TLS. "Enabled", which means that client communications may use TLS (but they also may not) and "Required", which forces all client communications to use TLS.

InterSystems documentation explains how to configure the server to require TLS: https://docs.intersystems.com/irislatest/csp/docbook/DocBook.UI.Page.cls?KEY=GSA_manage_superserver

For more information about how to configure a system to mitigate this vulnerability, contact InterSystems at their world wide response center: https://wrc.intersystems.com (login required)

icscert guidance ↗

cve.new guidance unless attributed to a publisher. This page does not inspect your installation.

Public exploit evidence

No public exploit reference is identified in the imported evidence. This is not a claim that no exploit exists.

Original source description

Read the full publisher description

InterSystems IRIS for Health has TLS/SSL encryption turned off by default, which may enable an attacker to view transmitted data and use that data to log into the device.

References

5 sources

Inside the record

Evidence available

Package identity · not supplied
Version evidence
Remediation guidance
Weakness classification
Additional publishers

Describes the evidence in this view, not whether the product is safe.

Original records

CVE-2026-111594

View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.

cve.new JSON →

Underlying weaknesses

The source’s classification of what caused the vulnerability.

Contributing organizations · 2
icscert

Assigning organization

2026-10-22
CISA-ADP

Additional data publisher

2026-11-02

Timeline

All times UTC
  1. Advisory published

    Publication date supplied by the source.

  2. Source updated

    Latest modification date supplied by the source.

  3. Last imported by cve.new

    Latest catalog import, not the date we first saw this advisory.

What changed

Follow changes
No substantive changes have been recorded here yet. History starts when cve.new observes a change after tracking is enabled; earlier edits are not reconstructed.

Large field values are marked as truncated previews. Original source snapshots remain retained.