Remote Code Execution in CGM CLININET
Severity and exploitation
KEV coverage does not rule out exploitation.
Assessment vector
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HSeverity
critical9.0CVSS measures technical severity, not the likelihood of an attack.
Known exploitation
Not listed in the checked CISA KEV catalog
Absence from CISA KEV does not rule out attacks.
Public exploit
Not established by this record
Missing evidence does not mean no public exploit exists.
Remediation
Fix status not established
No structured fix or guidance is available here. Check the latest publisher advisory.
What this means
In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges.
Source excerpt · CERT-PLAttack conditions
No attack-condition excerpt has been identified here. Review the full source description and references for authentication, network access, and configuration requirements.
Review supporting sources →Affected versions
Check the exact model, release, and any platform requirements against your installation.
CGM · CERT-PL
CGM CLININET
1 range
CGM · CERT-PL
CGM CLININET
Compare with this publisher’s ranges. This does not inspect your installation.
affected
0 → through 2026.MS3
custom versions
Other versions: unknown
What to do
Compare your installed product and version with the affected versions above. A matching product name alone does not confirm exposure.
No structured fix or remediation guidance is available here. Check the full source description and vendor’s latest advisory for a patch or workaround; do not assume another version is safe.
cve.new guidance unless attributed to a publisher. This page does not inspect your installation.
Public exploit evidence
No public exploit reference is identified in the imported evidence. This is not a claim that no exploit exists.
Original source description
Read the full publisher description
In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges.
The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.
References
2 sourcesInside the record
Evidence available
Describes the evidence in this view, not whether the product is safe.
Original records
CVE-2025-30046View the latest unmodified CVE JSON from the official source. It may be newer than this imported page.
cve.new JSON →Underlying weaknesses
The source’s classification of what caused the vulnerability.
Environment requirements
These conditions apply together as specified by the publisher. A matching product name alone does not establish exposure.
CERT-PL · platform conditions
Any condition may hold
Any condition may hold
Vulnerable product
cpe:2.3:a:cgm:cgm_clininet:*:*:*:*:*:*:*:*From (inclusive): 0
Through (inclusive): 2026.ms4
Applicability preview
[
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:cgm:cgm_clininet:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndIncluding": "2026.ms4"
}
]
}
]
}
]Contributing organizations · 2
Assigning organization
Additional data publisher
Timeline
All times UTCAdvisory published
Publication date supplied by the source.
Source updated
Latest modification date supplied by the source.
Last imported by cve.new
Latest catalog import, not the date we first saw this advisory.
What changed
Follow changesLarge field values are marked as truncated previews. Original source snapshots remain retained.